Monday, February 8, 2010

Agilent U1251A/U1252A/U1253A DMMs - Connect To Computer

Similarly to Fluke 189/289 DMMs
Agilent U1251A/U1252A/U1253A DMMs can be connected to a computer too. The Agilent DMMs need IR-USB U1173A cable for that.

Check U1251A/U1252A User’s and Service Guide for details. The same as with Fluke DMMs connection to the Agilent DMMs is represented as a COM port on system level:


Agilent provides its own software, Agilent GUI Datalogger, for measurement automation which is very convenient. However it is not a big deal to write a custom code for the Agilent DMMs if there is a necessity, for instance, to control some different devices from one program. Here is a screen shot of Agilent GUI Datalogger with the list of commands and the connection parameters:


Identification command "*IDN?" allows to find automatically the COM port assigned to the DMM, command "READ?" returns a measured value:



Read more...

Monday, February 1, 2010

Fluke 189/289 DMM - Connect To Computer

Some of multimeters as Fluke 189 or 289, for instance, can be connected to a computer. That allows easily to setup communication with such a device and automate measurements. Fluke 189/289 needs Fluke IR189USB cable for that. While it is USB port physical connection it's represented as a serial COM port on operating system level.

Has to be mentioned that Fluke provides its own software to communicate with the DMMs: FlukeView Forms. Nevertheless due to simplicity of the interface connection can be easily controlled from available in Windows HyperTerminal, for example, or from a simple custom program or script. The detailed list of commands and parameters of the communication protocol can be found here.

To set it up:
  1. Install drivers for corresponding operating system. FTDI USB chip is used in the cable, a corresponding driver is available for downloading from here.

  2. Connect a Fluke 189/289 to a computer USB port.

  3. Check what port number was assigned for the Fluke multimeter: Start/MyComputer/Properties/Hardware/Device Manager/Ports

  4. Open a serial terminal program, for example, Hyperterminal in Windows, choose the port and setup parameters of the connection as 9600 baud, 8 bits, no parity, 1 stop bit.

  5. Send commands and read responses:


Reading a currently measured value is done by sending out Query Measurement "QM" command. Identification "ID" command can be used to find automatically that port which Fluke DMM was assigned to.

Read more...